Our Products

DATEXEL din rail mounted 01

DAT20-2W   Fixed range transmitter for mV,V and mA signals
• Input for current or voltage signals • Zero and Span values adjustable by potentiometers • 4÷20 mA current loop output • High accuracy • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN 50022 and EN-50035      send request
DAT20-3W   Converter for mV,V and mA signals
• Input for current or voltage signals • Zero and Span values adjustable by potentiometers • Output in voltage or current • Command SEL for enable / disable output • High accuracy • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN 50022 and EN-50035      send request
DAT2115   PC programmable universal signal converter
• Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer • Configurable output in current or voltage • Configurable by Personal Computer • High accuracy • On-field reconfigurable • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035      send request
DAT2115-SEL   Universal signal converter with command of enable/disable output
• Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer • Configurable output in current or voltage • Command “SEL” for enable/disable output • Configurable by Personal Computer • High accuracy • On-field reconfigurable • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035      send request
DAT2115   PC programmable universal signal converter
• Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer • Configurable output in current or voltage • Configurable by Personal Computer • High accuracy • On-field reconfigurable • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035      send request
DAT2145   Programmable converter for thermocouple
• Input for thermocouples type K, J, R, S and T • Unit of measure configurable in °C or °F • Zero and Span values configurable by DIP-switches • Voltage or current “voltage linear” output • Good accuracy and performance stability • EMC compliant – CE mark • DIN rail mounting in compliance with EN-50022 and EN-50035      send request
DAT2165   Converter not insulated for Pt100,configurable by dip switch
• Input for RTD type Pt100 • Unit of measure configurable in °C or °F • Zero and Span values configurable by DIP-switches • Linearised voltage or current output • Good accuracy and performance stability • EMC compliant – CE mark • DIN rail mounting in compliance with EN-50022 and EN-50035    

Login Form

Social Bookmark

FacebookMySpaceTwitterStumbleuponGoogle BookmarksRedditNewsvineTechnoratiLinkedinMixxRSS FeedPinterest

YM Online Staturs

Information

 

Inquiry

 

Visitors Counter

000296
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
154
0
154
0
154
0
296

Your IP: 52.91.90.122
Server Time: 2018-12-16 18:22:13

Join Our Newsletter!

Join with us now and Get the latest information about our product and service.

Your mail*


Thank You for your participate.