Our Products

DATEXEL din rail mounted 01

DAT20-2W   Fixed range transmitter for mV,V and mA signals
• Input for current or voltage signals • Zero and Span values adjustable by potentiometers • 4÷20 mA current loop output • High accuracy • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN 50022 and EN-50035      send request
DAT20-3W   Converter for mV,V and mA signals
• Input for current or voltage signals • Zero and Span values adjustable by potentiometers • Output in voltage or current • Command SEL for enable / disable output • High accuracy • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN 50022 and EN-50035      send request
DAT2115   PC programmable universal signal converter
• Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer • Configurable output in current or voltage • Configurable by Personal Computer • High accuracy • On-field reconfigurable • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035      send request
DAT2115-SEL   Universal signal converter with command of enable/disable output
• Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer • Configurable output in current or voltage • Command “SEL” for enable/disable output • Configurable by Personal Computer • High accuracy • On-field reconfigurable • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035      send request
DAT2115   PC programmable universal signal converter
• Configurable input for RTD, TC, mV, V, mA, Resistance and Potentiometer • Configurable output in current or voltage • Configurable by Personal Computer • High accuracy • On-field reconfigurable • EMC compliant – CE mark • Suitable for DIN rail mounting in compliance with EN-50022 and EN50035      send request
DAT2145   Programmable converter for thermocouple
• Input for thermocouples type K, J, R, S and T • Unit of measure configurable in °C or °F • Zero and Span values configurable by DIP-switches • Voltage or current “voltage linear” output • Good accuracy and performance stability • EMC compliant – CE mark • DIN rail mounting in compliance with EN-50022 and EN-50035      send request
DAT2165   Converter not insulated for Pt100,configurable by dip switch
• Input for RTD type Pt100 • Unit of measure configurable in °C or °F • Zero and Span values configurable by DIP-switches • Linearised voltage or current output • Good accuracy and performance stability • EMC compliant – CE mark • DIN rail mounting in compliance with EN-50022 and EN-50035    

Login Form

Social Bookmark

FacebookMySpaceTwitterStumbleuponGoogle BookmarksRedditNewsvineTechnoratiLinkedinMixxRSS FeedPinterest

YM Online Staturs

Information

 

Inquiry

 

Visitors Counter

358019
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
17
203
830
355975
3070
4741
358019

Your IP: 18.212.206.217
Server Time: 2019-02-21 00:14:22

Join Our Newsletter!

Join with us now and Get the latest information about our product and service.

Your mail*


Thank You for your participate.